Single Channel ECG Machine

(Out Of Five)

Model: MSB-ECG-S-01

Products Short Description:

ECG100G is a kind of single-channel electrocardiograph, which features in printing ECG waveform by the thermal printing system, prompting for \"Leadoff\" or \"Lack of paper\", multi-language interface, recording ECG waveform in AUTO/Manual mode, convenient to operate.

  • Tk. 25000

Products Full Description:

1)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.

2)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.

3)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).

4)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.

5)Multi-language (Chinese, English, French, Italian, German, Spanish and Turkish) interface and report.

6)In optimal DC state, up to 7-hour standby time, continuous print up to 4-hour, record up to 150 ECG waveform.

Technical Specification:

Performance

Input mode: floating and defibrillation protection

Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)

CMRR: >60dB, >100dB(add filter)

Time constant:≥ 3.2s

Patient leak current: <10µA

Calibration voltage: 1mV

Sensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%

Noise level: ≤15µVp-p

Input circuit current: ≤50nA

Input impedance: ≥50MΩ

Sampling accuracy: 12-bit

Safety classification: class I, type CF and defibrillation-proof applied part

Recording mode: thermal printing system

Paper size: 50mm(W)×20m(L)

Sampling frequency: 800Hz

EMG interference filter: 35Hz (-3dB)

Power frequency filter: AC 50Hz/60Hz(-20dB)

Paper speed: 25, 50mm/s, ±5%

Power supply:

AC: 100V~240V(50/60Hz)

DC: 7.4V/2000mAh rechargeable lithium battery

Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V

Waterproof degree: IPX0

Working mode: continuous working

 

Accessories

 

Standard:

A lead cable

A limb electrode

A chest electrode

A thermal recording paper

A power cord

An earth wire

A user manual

 

Optional:

ECG electrode

Bag

Conductive gel

 

Physical characteristic

 

Working environment

Temperature: 5℃~40℃

Relative humidity: 25%~95%(non-condensing)

Atmospheric pressure: 700hPa~1060hPa

Transport and storage environment

Temperature: -40℃~+55℃

Relative humidity: ≤95%

Atmospheric pressure: 500hPa~1060hPa

Dimension: 315mm(L) × 215mm(W) × 77mm(H)

Weigh: 1.5Kg

Products Origin:  Made in China

Brand Name: Contec Medical System

Warranty: One Years